B&R Industries Provit 5000 User Manual - page 39
38
Provit 5000 User’s Manual
Controllers • Technical Data
1.2 Bus Units
1.2.1 IPC5000 and IPC5000C
5) When using the processors 5C5002.14 (Celeron 566) with the system unit 5C5001.1x , the maximum operating temperature is revision
number
≤
D0 45°C.
Bus Units
5C5000.01
1)
2)
3)
1) A 3 pin cable with grounding contact plug is required for operation (order no. 9A0001.03)
2) The maximum operating temperature of the IPC is 45°C, when using the processor 5C5002.13 (Celeron 433) with the system unit
5C5001.1x.
3) When using the processors 5C5002.14 (Celeron 566) with the system unit 5C5001.1x , the maximum operating temperature is with
revision
≤
D0 45°C.
5C5000.02
4)
4) A plug (with terminal blocks) for connecting to the supply is contained in the delivery. The cable must be provided by customers.
5C5000.11
5C5000.12
Slots
5)
Total
B&R ISA 16 Bit
6)
Half Size ISA 16 Bit
Half Size ISA 16 Bit/PCI 32 Bit
Half Size PCI 32 Bit
Full Size ISA 16 Bit
Full Size ISA 16 Bit/PCI 32 Bit
Full Size PCI 32 Bit
5) All PCI slots have an operating voltage of 5V and a clock frequency of 33MHz.
6) Standard 16 bit ISA interface, with specific mechanical requirements.
2
1
-
1
-
-
-
-
4
1
-
3
-
-
-
-
Supply Voltage
100 - 240 VAC
50 - 60 Hz
24 VDC
100 - 240 VAC
50 - 60 Hz
24 VDC
Fan Type / Design
Ball bearings, analog control
Number of Fans
∅
40 mm
2
3
2
Table 16: Technical data for IPC5000 bus units
Bus Units
5C5000.21
1) 2) 3)
5C5000.22
2) 3) 4)
5C5000.31
5C5000.32
Slots
5)
Total
B&R ISA 16 Bit
6)
Half Size ISA 16 Bit
Half Size ISA 16 Bit/PCI 32 Bit
Half Size PCI 32 Bit
Full Size ISA 16 Bit
Full Size ISA 16 Bit / PCI 32 Bit
Full Size PCI 32 Bit
2
-
-
1
1
-
-
-
5
1
1
1
2
-
-
-
Supply Voltage
100 - 240 VAC
50 - 60 Hz
24 VDC
100 - 240 VAC
50 - 60 Hz
24 VDC
Fan Type / Design
Ball bearings, analog control
Number of Fans
∅
40 mm
∅
50 mm
2
-
1
2
1
1
Table 17: Technical data for IPC5000 bus units