Display Units • Displays 5D5500.10, 5D5500.32, 5D5501.01 and 5D5510.10
18.5 Mounting Guidelines
When mounting the display unit on the controller unit (standard mounting) the display is fastened
to the controller with the six screws included in the delivery. The FPD connection cable and a
cable for connecting further Panelware modules are included in delivery.
The function keys are treated like Panelware modules. As a result, the same regulations apply
to the connection, particularly in regard to the maximum number of keys (see the section "Using
Panelware Modules").
Transfer of the key codes from display to controller is made using the FPD cable and
not with a separate cable. The existing Panelware cable on the display is used as
output (for further Panelware modules) and not as input.
Figure 139: Connections 5D55xx.xx