9.8 Power Failure Bypass Function of the Bus Units
9.9 Functional Ground Connection
It is possible to connect the bus unit with functional ground, which supports the device's function
and noise suppression. The connection is made with a cable on a part of the housing which is
grounded (e.g. switching cabinet, etc.). A suitable cable with a plug must be supplied by the
customer.
Bus Unit
Supply Voltage
Power
Power Failure Bypass
5C5000.01
100 - 240 VAC
60 W
20 ms for 60 W load
5C5000.02
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5000.11
100 - 240 VAC
100 W
20 ms for 80 W load
5C5000.12
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5000.21
100 - 240 VAC
100 W
20 ms for 80 W load
5C5000.22
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5000.31
100 -240 VAC
100 W
20 ms for 80 W load
5C5000.32
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5600.01
115 / 230 VAC
100 W
20 ms for 100 W load
5C5600.02
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5600.03
115 / 230 VAC
100 W
20 ms for 100 W load
5C5600.04
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
5C5600.11
115 / 230 VAC
100 W
20 ms for 100 W load
5C5600.12
24 VDC
60 W
1.5 ms for + 5 V and 1 ms for + 12 V with 150 W load
Table 104: Power failure bypass function for Provit bus units
Figure 78: Functional ground connection for IPC5000 and IPC5000C (4 slot design)