Controllers • System Units with Socket 370
8.9 Interface for External Floppy Disk Drive
An external floppy disk drive can be connected to the 25 pin DSUB socket (see Chapter 7
"Accessories").
It is not possible to operate a second parallel device on this interface.
These settings cannot be changed.
Because of general PC specifications, this interface should be handled with extreme
care with regard to EMC, location of cables etc. It should therefore only be used for
service.
Interface for External Disk Drive
Pin
Assignment
Pin
Assignment
25 pin DSUB socket
1
n.c.
14
Density
2
Index
15
Side Select
3
Track 0
16
Direction
4
Write Protect
17
Step
5
Read Data
18
GND
6
Disk. Chan.
19
GND
7
n.c.
20
GND
8
n.c.
21
GND
9
+5 V
22
GND
10
Drive Select
23
GND
11
Motor on
24
GND
12
Write Data
25
GND
13
Write Gate