Oce Arizona T220UV User Manual - Uv Lamp Reflectors
Maintenance Guidelines |
6/2/04
7-103
Since you will never know when a lamp will burn out or exhibit sub-standard levels of
UV energy, it is a good policy to keep an inventory of replacement lamps. The best
solution is to maintain one lamp for each lamp in service. This will protect against any
problem that may arise, as well as have on hand the lamps required for a scheduled
change.
UV Lamp Reflectors
Regular maintenance inspections should also include reflector evaluation. How clean are
the reflectors? Dirty reflectors will cut down cure efficiency in a very dramatic way.
7.1.3
Operator Maintenance Schedule
The Arizona T220UV printer requires some daily maintenance. Periodic cleaning should
be scheduled for some components during the week. A few minutes spent cleaning
ensures the highest quality prints. Several areas require maintenance to ensure the
highest print quality, and the printer design gives you easy access to all these areas.
Diligent application of the Arizona T220UV Printer Operator Maintenance Schedule
Guidelines (see Table 17 on page 103) ensures optimum performance from your printer.
7.1.4
Recommended Maintenance Frequencies
Table 17Arizona T220UV Printer Operator Maintenance Schedule Guidelines
Description
Location in Manual
Frequency
Remove Ink from Table
“Removing Ink From the Table” on page 104
Daily
Carriage Underside
“Clean Carriage Underside” on page 105
Weekly
Gantry Rails
“Clean Gantry Rails” on page 108
Monthly
Air Filter
“Air Filter (Electronics Enclosure)” on page 111
Every 6 months
Coalescing Filter
“Filter Element in Air Regulator Auto-Drain” on
Every 6 months
Linear Encoders
“Linear Encoders (Table and Gantry)” on page 111
Every 6 months