Oce Arizona T220UV User Manual - page 15
General Description |
6/2/04
1-3
1.1.4
Vacuum Pump Power Requirements
The vacuum pump operates over the following range of voltages and frequencies:.
230 Volts @ 60HZ
Voltage:......................230 VAC +/-10%, 3 Phase
Current:......................13 AMPS maximum steady state
Power: .......................6kW max.
Circuit Breaker ...........20 Amps
400 Volts @ 60Hz
Voltage:......................400 VAC +/-10%, 3 Phase
Current:......................8 AMPS maximum steady state
Power: .......................6kW max.
Circuit Breaker ...........15 Amps
190 Volts @ 50 Hz
Voltage:......................190 VAC +/-10%, 3 Phase
Current:......................16.5 AMPS maximum steady state
Power: .......................8kW max.
Circuit Breaker ...........20 Amps
380 Volts @ 50 Hz
Voltage:......................380 VAC +/-10%, 3 Phase
Current:......................8 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker ...........15 Amps
1.1.5
Maximum System Impedance
This equipment may only be connected to mains connections with an impedance at 50Hz
of
Z
sys
= 0.3409
Ω
or less. In case it is observed that this equipment causes 'lightflicker'
to the environment, contact the supply authority in order to verify if the mains network
has a lower impedance than the one specified above.
Note:
ODGS recommends that the AC power outlet for the vacuum pump be
located within 8 feet of the power inlet on the pump.
Unplugging the power cord from the wall socket is the only way to isolate
the entire machine.