Troubleshooting Tips
This section contains some potential problems you may encounter with your Arizona
T220UV Printer and offers possible solutions. If your problem is not solved by these or
other suggestions in the Maintaining Print Quality section, place a service call for
qualified technical support.
“Carriage temp is too high”
“print cancelled, press ACCEPT”
The carriage temperature has exceeded its
maximum range. There may be a fan not
working or other mechanical failure relating to
the cooling system (air flow). The printer may
also be printing above its operating range.
Check that the room temperature is not too
high and that all fans are working.
"Carriage out of safety zone"
"press ACCEPT to continue"
The carriage has stopped with its lamps on in
the middle of the gantry. If problem persists,
call for service
Problem
Solution
Cannot initialize
T220UVPrinter
Make sure the T220UVI/O is set to SCSI and not
Parallel. Also for Windows 2000 and XP, go into the
System / Hardware Settings / Device Manager and
disable the generic printer listed under IEEE 1394
devices and SCSI printers.
Rebooting the Computer
during Printing hangs the
printer
This is not recommended, because when the computer
initializes the SCSI host adapter, it may hang the printer.
Table 16
Error Message
Possible Cause and Response