System Errors
System errors stop the printer and prevent operation until the error is resolved. Many
system error messages indicate the source of the problem and state that the error can be
cleared by pressing the ACCEPT button on the control panel. If the problem persists,
record the error message and contact your Océ Display Graphics Systems service
representative.
Table 16
Error Message
Possible Cause and Response
“WARNING: SAFETY INTERLOCK
BYPASSED”
Refer to possible causes in section
"SYSTEM ERROR [press ACCEPT
to restart]"
"BLOTTER MOTOR or ENCODER"
The blot cloth is not moving. Might be out of
cloth or stuck.
"Lamp Warmup timeout.
Cancelling print"
"Press ACCEPT to Continue"
The illuminator could not reach its minimum
temperature (default 120F/49C ) in its allotted
time (10 minutes). Might be a sensor problem
or bad cabling - call for service.
“Lamp xx is out, uv power is off”
“press ACCEPT to continue”
The lamp(s) have unexpectedly gone off.
This error should be recorded, but no action
is required unless the problem is persistent. If
persistent, a service call is in order.
“Reflector overtemp interlock open”
“press ACCEPT to continue”
Illuminator overtemp pop out has triggered.
Possible problem with illuminator fan or other
cooling problem. Check that the lamp is on
and also that the carriage fan is plugged into
the carriage cover and the gantry fans are all
running. If problem persists, call for service.