Qlogic 3200 Series User Manual - page 277
9–Converged Network Adapter Interactive Commands
Transceiver Diagnostics Monitoring Interface (DMI)
SN0054667-00 B
9-91
--------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Media Information
--------------------------------------------------------------------------------
Vendor: FINISAR CORP.
Type: 10G Base-SR
Part Number: FTLX8571D3BCL-QL
Speed: 10 Gbits/Sec
Revision: A
Serial Number: AH208K5
QLogic SFP Installed: Yes
--------------------------------------------------------------------------------
Temperature Voltage Tx Bias Tx Power Rx Power
(C) (V) (mA) (mW) (mW)
-------------- ------- ------- -------- --------
Value 36.45 3.36 8.31 0.6040 0.6625
Status Normal Normal Normal Normal Normal
High Alarm 78.00 3.70 11.78 0.8318 1.0000
High Warning 73.00 3.60 10.80 0.6607 0.7943
Low Warning -8.00 3.00 5.00 0.3162 0.0158
Low Alarm -13.00 2.90 4.00 0.2512 0.0100
Details
9. Transceiver Diagnostics Monitoring Interface (DMI)
From the Transceiver Diagnostics Monitoring Interface (DMI) menu, select the
Details option to view detailed DMI diagnostic information. For example:
--------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
--------------------------------------------------------------------------------
Optical Transceiver Digital Diagnostic Data:
Address A0
Identifier: SFP
Ext. Identifier: GBIC/SFP defined by serial ID only
Connector: LC
Ethernet Speed: 10 Gbits/Sec
Compliance: 0x00 0x00 0x00
FC Link Length:
FC Transmitter Tech:
FC Transmission Media:
FC Speed:
Encoding: Reserved
BR, Nominal: 0x67
Length (9um) - km: 0x00
Length (9um): 0x00
Length (50um): 0x08