Qlogic 3200 Series User Manual - page 92
5–Fibre Channel Noninteractive Commands
-kr (Run Read/Write Buffer Test)
5-22
SN0054667-00 B
If the read/write buffer test fails, the system shows the following information:
Loop/port ID (the loop ID of the adapter when operating in loop mode).
Status:
Success—The test passed.
Error—A data miscompare or link status firmware error occurred.
Failed—A link status error, SCSI write buffer error, or SCSI read buffer
error occurred.
Unknown—The target was not present.
Unsupported—The device does not support this test.
Data Miscompare—The possible values are:
0 (no data miscompares)
Device not present
Get link status failed
Read buffer failed
R/W buffer not supported
Write buffer failed
Link Failure—Number of link failures
Loss of sync—Number of sync loss errors
Loss of signal—Number of signal loss errors
Invalid CRC—Number of invalid CRCs
Table 5-7. Data Pattern (DP) Test Patterns
Hex
Binary
00
00000000
55
01010101
5A
01011010
A5
10100101
AA
10101010
FF
11111111