Qlogic 3200 Series User Manual - page 91
5–Fibre Channel Noninteractive Commands
-kr (Run Read/Write Buffer Test)
SN0054667-00 B
5-21
DataSize
e
DS
8, 16, 32, 64, 128, 256,
512, 1024, 2048
Actual data transferred dur-
ing any given pass of the
test
TestCount
f
TC
0–65535
0–10,000
Loopback test only
Read/write buffer test only
TestIncrement
g
TI
1–65535
1–10,000
Loopback test only
Read/write buffer test only
OnError
OE
0–2
0 = ignore
1 = stop
2 = loop on error
LoopbackType
h
LT
0–2
0 = 10-bit internal loopback
i
1 = 1-bit serial loopback
2 = external loopback
a
Valid two-character case-insensitive hexadecimal patterns.
b
Compliant random data pattern in a valid Fibre Channel frame, as defined by the ANSI document
Methodologies for Jitter and Signal Quality Specification—MJSQ Annex A —Test bit sequences.
c
Compliant jitter tolerance pattern in a Fibre Channel frame, as defined by the ASIC document listed
above.
d
Compliant supply noise test sequence in a valid Fibre Channel frame, as defined by the ASIC
document listed above.
e
For read/write buffer test, the maximum size is 128; this is also the default.
f
0=test continuously. 1–10,000 and 1–65535=total number of tests that will be executed.
g
Must be less than the TestCount value.
h
Loopback test only
i
Requires installation of a loopback plug in the port SFP
Table 5-6. Diagnostics Parameters (Continued)
Name
Alias
alias>
Value
Description