6.7 Cleaning the developer station
A29246-X20-X-4-7680 / fa603.fm
205
9.
Pull the developer station outwards by
the handle to the stop point.
Caution
There can be a high build-up of static charge when vacuuming the toner spill.
Always use an industrial vacuum cleaner with a grounded suction tube, rubber
nozzle and filter set for fine dust. For larger quantities of toner spill (e. g. full bottle),
the industrial vacuum cleaner must be explosion-proof.
Important
Do not vacuum around the developer roller, as you might vacuum up developer mix.
When performing the following cleaning, only vacuum the specified parts.
10.
Using a vacuum cleaner, vacuum
toner, developer and paper residue
from the front suction bar, on the felt
and on the upper cover of the
developer station.
11. Push in the developer station by the handle until it reaches the stop point.
Proceed as follows:
3 of 4