7.2.4 Replacing the developer
238
A29246-X20-X-4-7680 / fa701.fm
7.2.4 Replacing the developer
Observe the following safety directives when replacing the developer:
The printer detects the end of the developer's service life automatically and displays a
warning on the operator panel in good time.
The following procedure is for developer replacement:
- Empty developer station >>> page 239
- Filling new developer >>> page 244
Caution
• Do not allow developer to get into eyes. In the event of contact with eyes, rinse eyes
out with plenty of water and seek medical help.
• Avoid contact with the skin; wear gloves. In the event of contact with skin, wash
developer off with plenty of water.
• Do not inhale developer. Avoid accumulation of dust. If, after inhaling developer, you
experience symptoms such as nausea, headaches or dizziness, immediately go out
into the fresh air.
• Do not spill developer. There is a danger of slipping on spilled developer. Clean up
developer spill immediately.
• Always use an industrial vacuum cleaner with a grounded suction tube, rubber
nozzle and filter set for fine dust. For larger quantities, the industrial vacuum cleaner
must be explosion-proof.
• Keep developer out of the reach of children and store it away from containers used
for food and drink.
Important
• Use only permitted developer (see section Consumables, page 356).
• Only use original, sealed developer bottles for refilling.
• Do not re-use used developer.
• Always store developer in a cool (< 35
o
C), dry and well ventilated room.
• Never expose developer to direct heat (sunlight, heaters, etc.)
• Keep used developer ready for collection by service or the contracted shipping
company .
Note
The printing system will continue to print even when the end of the developer's service
life has been reached.
This means that the developer counter in the
register negative.