7.3.1 Replacing the photoconductor drum
A29246-X20-X-4-7680 / fa701.fm
257
7.3.1 Replacing the photoconductor drum
Strictly observe the following safety directives when replacing the photoconductor drum:
The following procedure is for replacing the PC drum:
- Remove photoconductor drum >>> page 258
- Install the the photoconductor drum >>> page 260
Pressure roller
7.3.9 Replacing the pressure roller >>> page 320
Waste collector
7.3.10 Replacing the waste collector >>> page 326
Fine filter
7.3.11 Replacing the fine filter >>> page 330
Caution
• The photoconductor drum may only be replaced by operators after training or
instructions from service personnel.
• When replacing the photoconductor drum, always wear the gloves provided.
Skin ailments can result from touching the photoconductor drum.
If you touch the drum, wash skin thoroughly with soap and water.
• Keep photoconductor drums out of the reach of children.
Important
• If pieces of the photoconductor drum coating flake off, you must collect all these
pieces.
Store old photoconductor drums with protective covers and any flakes of coating in
the original drum cartons, and keep ready for collection by service or the contracted
shipping company.
Photoconductor drums and collected flakes of coating require special disposal.
• If the photoconductor drum had only a short service life, the cause of the problem
must be identified in order to prevent further damage.
• Use only permitted photoconductor drums (see section Consumables, page 356).
• Store new photoconductor drums in appropriate conditions:
– Do not store together with flammable substances.
– Store in the closed original carton in a dry environment at 15 to 25
o
C .
Expendable