7.3.7 Replacing the heater
A29246-X20-X-4-7680 / fa703.fm
309
Caution
The components in the fuser station reach a surface temperature of approximately
230
o
C in operation.
If you touch them, you may burn yourself.
Put on heat protection gloves to continue working.
5.
Put on heat protection gloves.
6.
Carefully remove the faulty heater
from the storage opening.
7.
Place the faulty heater in the empty packaging, close and make ready for collection
by service.
8.
Close the right door at the back of the printing system.
Proceed as follows:
3 of 5