Quanta Computer QuantaMesh User Manual - page 221
UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
221
5.3.5.5 snmp-server community
This command adds (and names) a new SNMP community, and optionally sets the access mode,
allowed IP address, and create a view for the community.
Community names in the SNMP community table must be unique. If you make multiple
entries using the same community name, the first entry is kept and processed and all
duplicate entries are ignored.
Syntax
snmp-server community
no snmp-server community
manage it with a specified privileged level. The length of community-name can be up to 20
case-sensitive characters.
private (Read-Write/RW), or Super User (SU).
client IP mask value to denote a range of IP addresses from which SNMP clients may use that
community to access the device. A value of 0.0.0.0 allows access from any IP address. Otherwise,
this value is ANDed with the mask to determine the range of allowed client IP addresses.
no - This command removes this community name from the table. The name is the community name
to be deleted.
Default Setting
Two default community names:
‧
public, with read-only permissions, a view name of Default, and allows access from all IP
addresses.
‧
private, with read/write permissions, a view name of Default, and allows access from all IP
addresses.
Command Mode
Global Config
5.3.5.6 snmp-server community-group
This command configures a community access string to permit access via the SNMPv1 and SNMPv2c
protocols.
i