5.9.7.2.13 dos-control smacdmac
This command enables the Source MAC address = Destination MAC address (SMAC=DMAC) Denial of
Service protection. If the mode is enabled, Denial of Service prevention is active for this type of attack. If
packets ingress with SMAC=DMAC, the packets will be dropped if the mode is enabled.
Syntax
dos-control smacdmac
no dos-control smacdmac
no - This command disables the Source MAC address = Destination MAC address (SMAC=DMAC)
Denial of Service protection.
Default Setting
Disabled
Command Mode
Global Config
5.9.7.2.14 dos-control tcpfinurgpsh
This command enables the TCP FIN and URG and PSH and SEQ=0 checking Denial of Service
protections. If the mode is enabled, Denial of Service prevention is active for this type of attack. If
packets ingress having TCP FIN, URG, and PSH all set and TCP Sequence Number set to 0, the
packets will be dropped if the mode is enabled.
Syntax
dos-control tcpfinurgpsh
no dos-control tcpfinurgpsh
no - This command disables the TCP FIN and URG and PSH and SEQ=0 checking Denial of
Service protections.
Default Setting
Disabled
Command Mode
Global Config