Quanta Computer QuantaMesh User Manual - page 299
UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
299
This command sets the Edgeport BPDU Guard enable/disable parameter for accepting BPDUs on this
interface. This command only works on dot1d mode.
Syntax
spanning-tree bpduguard
no spanning-tree bpduguard
no - This command sets the Edgeport BPDU Guard to the default value, that is, Disabled.
Default Setting
Disabled
Command Mode
Interface Config
5.4.2.13 spanning-tree uplinkfast
This command sets the Uplink Fast parameter to a new value on this switch. This command only works
on dot1d mode.
Syntax
spanning-tree uplinkfast
no spanning-tree uplinkfast
no - This command sets the Uplink Fast parameter to the default value, that is Disabled.
Default Setting
Disabled
Command Mode
Global Config