Alarm messages and possible causes
6
96
11 Flow factor
Min. setting = 0.40
Max. setting = 1.90
Reference to the value range of the
flow
factor
.
Entered value is not permitted.
12 Transmission fault. No RS232
connection
An error has occurred during data trans-
mission to the control unit.
The data have not been transmitted.
14 Error by setting TELIMAT.
Alarm for the TELIMAT sensor.
This error message is displayed if the
TELIMAT status is not detected for more
than 5 seconds.
15 Memory full. Delete one private
fertiliser chart.
A maximum of 30 fertiliser charts can be
saved.
No additional saving possible.
16 Approach drop point
Yes = Start
Safety request before drop point is ap-
proached automatically.
The drop point can be set in the
Fer-
tiliser settings
menu.
Fast emptying.
17 Error by setting drop point.
The actuator for the adjustment of the
drop point cannot reach the set value.
Blockade.
No position feedback.
18 Drop point blocked
Actuator overloaded.
19 Defect by setting drop point.
Actuator defective.
20 Error on LIN bus participant:
[Name].
Communication problem.
Remove actuator.
Cable breakage.
21 Spreader overloaded!
The machine is overloaded.
Too much fertiliser in the hopper
23 Error by setting TELIMAT
The TELIMAT setting actuator cannot
reach the target value it is to be moved to.
Blockade.
No position feedback.
24 Error by setting TELIMAT
Actuator overloaded.
25 Defect by setting TELIMAT
Defective TELIMAT actuator.
No. Message in display
Meaning
Possible cause