Rauch QUANTRON-A Instruction Manual - page 90
Spreading operation with the QUANTRON-A control unit
5
84
5.3.2
Spreading operation with one section and in the boundary spreading
During the spreading operation, the sections can be changed gradually and the
boundary spreading can be activated. The figure below shows the operating
screen with activated limited border spreading and activated sections.
Figure 5.2:
Operating screen, one section left, boundary spreading side right
[1] Quantity change in boundary spreading
[2] Spreading side on the right in the boundary spreading
[3] Right spreading side is activated
[4] Reduce or increase left section
[5] Left section adjustable in 2 steps (VariSpread 2)
The spreading quantity on the left is set to the full working width.
The
Right boundary spread
function key has been pressed; the boundary
spreading function has been activated, and the application rate has been re-
duced by 20 %.
Press the
Reduce left spreading width
function key in order to reduce the
section by one step.
By pressing the
C/100%
key, full working width is reapplied immediately.
For TELIMAT versions without sensor only: By pressing the T key, the bound-
ary spreading is deactivated.
3
5
1
2
4