4
MAN scale: manual operation with scale value
1.
Open the
Machine settings > AUTO / MAN mode
menu.
2.
Select
MAN scale
in the menu.
The display shows the
metering slide opening
menu.
3.
Enter the scale value for the metering slide opening.
4.
Press the
Enter key
.
4.12.2: Entering values with the cursor keys, page 79
.
The operating mode setting is saved.
The
MAN scale
operating mode enables manual adjustment of the metering slide
opening during spreading.
Requirements:
The metering slides are open (activation with the
Start/Stop
key).
In the
MAN scale
operating screen, the icons for sections are filled in red.
Figure 4.18:
MAN scale operating screen
[1] Display of the current scale position of the metering slide
5.
For changing the metering slide opening press
F2
or
F3
.
F2
:
MAN+
to increase the metering slide opening
F3
:
MAN-
to reduce the metering slide opening.
NOTICE
In order to achieve an optimum spreading result in manual mode as well, we rec-
ommend using the values for metering slide opening and forward speed provid-
ed in the fertiliser chart.