Rauch QUANTRON-A Instruction Manual - page 103
Alarm messages and possible causes
97
6
32 Externally controlled parts may
move. Risk of injury through
squeezing and shearing!
Direct ALL persons out of the
danger zone. Read the instruc-
tion manual.
Confirm with ENTER
If the machine control unit is activated,
components may move unexpectedly.
Follow the displayed instructions only
if all risks have been eliminated.
34 The spreader ist set to reduced
disc speed. The idle measure-
ment cannot be started; Con-
firm this alarm to set the
machine back to normal
spreading mode.
The flow factor must lie within a range of
0.50 - 1.80
.
The newly calculated or entered flow
factor is outside this range.
36 Weighing quantity impossible.
Machine must stop.
Alarm message during weighing.
The
Weigh quantity
function can
only be carried out if the machine is at
a standstill and in a horizontal posi-
tion.
45 Error M-EMC sensors. EMC
control deactivated!
The sensor does not send any signals.
Cable breakage
Defective sensor
46 Spreading speed error. Ob-
serve spreading speed of
450..650 rpm!
The PTO speed is outside the range for
the M EMC function.
47 Left dosing error, hopper emp-
ty, outflow blocked!
Hopper empty
Outlet blocked
48 Right dosing error, hopper
empty, outflow blocked!
Hopper empty
Outlet blocked
49 Idle measurement implausible.
EMC control deactivated!
Defective sensor
Defective gearbox
50 Idle measurement impossible.
EMC control deactivated!
PTO speed not constant on the long run.
52 Error at hopper cover
Actuator overloaded
53 Defect at hopper cover
Actuator defective
54 Change TELIMAT position
The TEILMAT position does not corre-
spond to the condition notified by GPS
Control
No. Message in display
Meaning
Possible cause