Rauch QUANTRON-A Instruction Manual - page 44
Operation QUANTRON-A
4
38
Figure 4.9:
Prepare calibration operating screen
[1] Symbol above function key F4 to select right spreading side
[2] Symbol above function key F1 to select left spreading side
[3] The selected section is displayed.
Selecting the section:
5.
Set the spreading side on which the calibration is to be carried out.
Press the
F1
function key to select
left
spreading side.
Press the
F4
function key to select
right
spreading side.
The icon indicating the selected spreading side has a red background.
Running the calibration test:
6.
Press the
Start/Stop
key.
The metering slide of the previously selected section opens and the cali-
bration is started.
The
Run calibration
operating screen is displayed.
n
WARNING
Risk of injury during calibration
Rotating machine components and ejected fertiliser may cause
injury.
Before starting
the calibration, it is to be ensured that all
preconditions have been met.
Observe the
calibration
chapter in the operating manual of
the machine.
NOTICE
The calibration can be stopped at any time by pressing the
ESC key
. The me-
tering slide is closed and the
Fertiliser settings
menu is displayed.
2
3
1