Rauch QUANTRON-A Instruction Manual - page 35
Operation QUANTRON-A
29
4
Entering the remaining quantity when refilling:
1.
Open the
Weighing trip counter > Rest (kg, ha, m)
menu.
The remaining quantity from the last spreading process is displayed.
2.
Fill the hopper.
3.
Enter the new total weight of the fertiliser in the hopper.
See also chapter
4.12.2: Entering values with the cursor keys, page 79
4.
Press the
Enter key
.
The device calculates the values for the possible spread area and the
possible spread distance.
5.
Press the
kg
key.
The operating screen is displayed again.
Calling up the residual quantity during spreading:
During spreading, the remaining quantity is continuously recalculated and dis-
played. See chapter
5: Spreading operation with the QUANTRON-A control unit,
.
4.3.3
Tare scales (AXIS-M 30.1 EMC + W only)
In this menu, the weighing value for the empty hopper is to be set to 0 kg.
For taring the scales, the following requirements have to be fulfilled:
the hopper is empty,
the machine is at a standstill,
the PTO shaft is switched off,
the machine is in a horizontal position and off the ground,
the tractor is at a standstill.
Taring the scales:
1.
Open the
Weighing trip counter > Tare the scales
menu.
2.
Press the
Enter key
.
The weighing value for the empty scale is now set to 0 kg.
The Weighing trip counter menu is displayed.
NOTICE
The application rate and working width values
cannot
be changed in this menu.
These values are for information only.
NOTICE
Tare the scales before each use in order to ensure problem-free calculation of
the remaining quantity.