Rauch QUANTRON-A Instruction Manual - page 58
Operation QUANTRON-A
4
52
The number of pulses of the speed signal must still be specified below. If you
know the exact number of pulses, you can enter it directly:
8.
Open the
Tractor (km/h) > New calibration > Imp/100m
menu item.
The Pulses menu for manual pulse count input is displayed.
Entering values into the control unit is described in section
ues with the cursor keys, page 79
.
If the exact pulse count
is unknown
, a
calibration
has to be started.
9.
Press the
F4 (100 m AUTO)
function key.
The calibration run operating screen is shown in the display.
Figure 4.17:
Calibration run speed signal operating screen
[1] Pulse display
[2] Start recording pulses
[3] Stop recording pulses
10.
Press
F4
[2] at the starting point of the reference distance.
The pulse display is now on zero.
The control unit is ready for counting pulses.
11.
Drive along the 100m long reference distance.
12.
Stop tractor at the end of the reference distance.
13.
Press the
F1 [3]
function key.
The display shows the number of received pulses.
14.
Press the
Enter key
.
The new pulse count is saved.
The calibration menu is displayed again.