Press the
Start/Stop
key once more.
The calibration is finished.
The metering slide is closed.
The display shows the
Input collected weight
menu.
Recalculating the flow factor
8.
Weigh collected weight (taking into account the empty weight of the collecting
vessel).
9.
Input collected weight.
Refer to chapter
4.12.2: Entering values with the cursor keys, page 79
10.
Press the
Enter key
.
The new value is saved in the control unit.
The
Flow factor calculation
menu is displayed.
11.
Determine the flow factor.
For taking over the
newly calculated
flow factor, press the
Enter key
.
For confirming the
previously saved
flow factor, press the
ESC key
.
The flow factor is saved.
The Move to drop point alarm message appears in the display.
The Fertiliser settings menu is displayed.
NOTICE
The calibration time is not relevant to the accuracy of the results. However,
a
minimum of 20 kg
should be calibrated.
n
WARNING
Risk of injury due to rotating machine components
Contact with rotating machine components (universal drive shaft,
hubs) may cause bruises, abrasions and crushing injuries. Body
parts or objects may be caught or pulled in.
Switch off the tractor motor.
Switch off the PTO and secure it against unauthorised acti-
vation.
NOTICE
The flow factor must be between 0.4 and 1.9.