Rauch QUANTRON-A Instruction Manual - page 42
Operation QUANTRON-A
4
36
4.5.4
Drop point
1.
Open the
Fertiliser settings > Drop point
menu.
2.
Determine the position for the drop point using the fertiliser chart.
3.
Enter the determined value in the input field.
Refer to chapter
4.12.2: Entering values with the cursor keys, page 79
.
4.
Press the
Enter key
.
The Fertiliser settings window with the new drop point is displayed.
If the drop point is blocked, alarm 17 is displayed. Refer to chapter
sages and possible causes, page 95
4.5.5
TELIMAT rate
In this menu, the TELIMAT quantity reduction can be set (in percent). This setting
is used for the activation of the boundary spreading function via the TELIMAT
sensor or the
T key
.
Entering the TELIMAT rate:
1.
Open the
Fertiliser settings > TELIMAT rate
menu.
2.
Enter the value in the input field.
Refer to chapter
4.12.2: Entering values with the cursor keys, page 79
3.
Press the
Enter key
.
The fertiliser settings window with the new TELIMAT rate is displayed.
n
CAUTION
Risk of injury due to automatic adjustment of the drop point!
With machines equipped with electrical drop point actuators, the
Move to drop point
alarm message appears. Upon activation of
the
Start/Stop
key, the drop point is automatically moved to the
preset value by means of the electrical actuating cylinders. This
may cause injury and property damage.
Before pressing
Start/Stop
, ensure that nobody is present
in the danger zone of the machine.
NOTICE
It is recommended to reduce the application rate at the boundary by 20 %.