Eclipse V12LD User Manual - 6.15 Shift Menu
V-Series Panels| User Guide
Page 139
Cross-point level control.
Microphone gain.
Loudspeaker cut.
Head-set select.
Microphone mute.
Side-tone control
General purpose inputs and outputs are not mimicked or remotely controllable
as they may not be connected to the same hardware on the supervisor and
target panels.
In particular, some of the general-purpose inputs and outputs have dedicated
functions on a Supervisor Panel. Busy Feedback is not mimicked.
Pushbutton panels can supervise lever key panels but will not be able to mimic
or control lever key up assignments. Only the lever key down assignments will
be supervised.
6.14.1.2 Exiting supervise mode
To exit Supervise mode, hold down the Menu button on the dial pad for at least
3 seconds. The key displays on both panels will then return to the normal
(non-supervised) state.
6.14.1.3 Supervisor hot key
A supervisor hot key can be configured in EHX to enable rapid entry to
Supervise mode. When the supervisor hot key is selected the labels to panels
which may be supervised will flash and the Reply key will display SUPERVISE
in highlighted mode.
Pressing the Reply key or Reply key talk button will exit this mode.
6.15 SHIFT menu
The SHIFT (Shift Page) menu enables access to the eight shift pages. Each
shift page displays a different set of key labels.
Shift Page Mode: when the Shift Page Menu is open, the keys on the panel
will be color coded.
Green: Keys are configured on the page
Red: No keys are configured on the page
Note: From the EHX software (Configuration > Preferences > Panel & Key
Operation), you can configure the panel shift key to only open the shift menu
after holding down the key for three seconds or longer. The usual time delay is
about 500 ms. For more information, see the EHX Software User Guide.