Pin
Wire color
Description / function
1
White
/
Orange
not used
2
Orange
not used
3
White
/
Green
Rx (+)
4
Blue
Tx (+)
5
White
/
Blue
Tx (-)
6
Green
Rx (-)
7
White
/
Brown
not used
8
Brow
n
not used
Table 9: AES-6 to panel wiring (CAT5 cable)
The AES-3 interface RJ45 connection is capable of operation with up to 200m
of screened Cat5e cabling of 110 ohm +/- 10 ohm impedance, with 24 AWG
cores.
If 26AWG or smaller cable is used the maximum cable run may be severely
reduced.
The specification for the coaxial cable required to connect V-Series panels AES-
3 interfaces to an AES-6-CX card is given below.
Characteristic
Requirement
Nominal impedance
75 Ohm
Insulation
solid polyethylene
Screen
double braided copper
Capacitance
68pF/m or better
Equivalents
BBC PSF 1/3M
BICC TM 3304
Brand Rex GT 851
Table 10: Coaxial cable specification
This type of cable will allow up to 500 meters of cable run between the AES-6-
CX interface and the panel at the standard 48K sample rate.
Note: A ferrite core must be added to the socket end of each cable. A suitable ferrite
core is Würth Electronik part: 74271132.
If the AES-3 option/AES-6 interface is used to connect the V-Series panel using
a 3rd-party AES-3 network the system setup is as shown below.
Figure 4-19: Panel connected by 3