Eclipse V12LD User Manual - 6.18 Ip Setup Menu
V-Series Panels| User Guide
Page 142
IP-enabled V-Series panels can connect to an Eclipse or Eclipse HX matrix over
a standard Ethernet network using an IVC-32 card. Each IVC-32 card can
support up to 32 V-Series panels using IP.
IP-enabled V-Series panels also support an additional two channels using IP
that you can use to connect 4-wire devices directly to the panel.
The IP settings for the panel are configured using the IP configuration menus,
described in this chapter.
V-Series panels running application code V1.73 or above are
automatically IP-enabled. V-Series panels running earlier versions of
the application code must be enabled for IP operation by either:
Inputting a ten digit passcode to the panel.
Upgrading to V1.73 or above of the application code.
6.17 Accessing the IP configuration menus
To access the IP menus, select Menu and then Info. The panel displays the
Local Maintenance Menu (LLM). Select IP SETUP to enter the IP
configuration menus.
Note: If you enter PANEL INFO instead, you enter the maintenance menus. See
7 Maintaining V-Series panels.
To communicate to ECS / EHX that the panel is ready to be identified, select
IDENTIFYME.
The panel buttons or LEDs
flash red
and IDENTIFYME is displayed in the
bottom left display screen. Select IDENTIFYME again (the Reply key) to
cancel identify mode.
Identification mode can also be initiated in ECS /EHX, in which case the same
display mode is seen.
Note: If the LAN port is the only connection with the panel, the panel will
automatically display the IP SETUP menu, prompting the user to enable the
panel for IP access (if it is not already enabled (see above)).
6.18 IP SETUP menu
Figure 6-109: IP Setup menu for rack mounted panels