D-Link xStack DGS-3600 Series User Manual - Sflow Analyzer Settings
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
sFlow Version
This displays the current sFlow version.
sFlow Address
This displays the sFlow IP address.
sFlow Analyzer Settings
The following windows are used to configure the parameters for the remote sFlow Analyzer (collector) that will be used to gather
and analyze sFlow Datagrams that originate from the Switch. Users must have the proper sFlow software set on the Analyzer in
order to receive datagrams from the switch to be analyzed, and to analyze these datagrams. Users may specify up to four unique
analyzers to receive datagrams, yet the virtual port used must be unique to each entry.
To configure the settings for the sFlow analyzer, click the
Administration
link, open the
sFlow
folder and click
sFlow Analyzer
Settings
, which will produce the following window, displaying the parameters for the sFlow Analyzer.
Figure 6- 55. sFlow Analyzer Settings window
The following fields are displayed:
Parameter Description
Server ID
This field denotes the ID of the Analyzer Server that has been added to the sFlow settings. Up
to four entries can be added, but each entry must have its own unique UDP Port.
Owner
Displays the owner of the entry made here. The user that added this sFlow analyzer
configured this name.
Timeout
Displays the configured time, in seconds, after which the Analyzer server will time out. When
the server times out, all sFlow samples and counter polls associated with this server will be
deleted.
Countdown Time
Displays the current time remaining before this Analyzer server times out. When the server
times out, all sFlow samples and counter polls associated with this server will be deleted.
Address
Displays the IP address of the sFlow Analyzer Server. This IP address is where sFlow
datagrams will be sent for analysis.
Port
Displays the previously configured UDP port where sFlow datagrams will be sent for analysis.
Only one Analyzer Address can be set for one UDP Analyzer Port.
Max Datagram Size
This field displays the maximum number of data bytes in a single sFlow datagram that will be
sent to this sFlow Analyzer Server.
Modify
Click the
Modify
button to display the
sFlow Counter Analyzer Edit
window, so that users
may edit the settings for this server.
Delete
Click the
of the corresponding entry to be deleted.
To add a new sFlow Analyzer, click the
Add
button in the previous window that will display the following window to be
configured: