D-Link xStack DGS-3600 Series User Manual - Sflow Poller Settings
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
The following fields may be set:
Parameter Description
From
Choose the beginning port of the range of ports to be configured for packet sampling.
To
Choose the ending port of the range of ports to be configured for packet sampling.
Analyzer Server ID
(1-4)
Enter the previously configured Analyzer Server ID to state the device that will be receiving
datagrams from the Switch. These datagrams will include the sample packet information taken
using the sampling mechanism configured here.
Rate (0-65535)
Users can set the rate of packet sampling here. The value entered here is to be multiplied by
256 to get the percentage of packets sampled. For example, if the user enters a figure of 20
into this field, the switch will sample one out of every 5120 packets (20 x 256 = 5120) that pass
through the individual port. Users may enter a value between
1
and
65535
. An entry of
0
disables the packet sampling. Since this is the default setting, users are reminded to configure
a rate here, otherwise this function will not function.
Max Header Size
(18-256)
This field will set the number of leading bytes of the sampled packet header. This sampled
header will be encapsulated with the datagram to be forwarded to the Analyzer Server. The
user may set a value between
18
and
256
bytes. The default setting is
128
bytes.
Click
Apply
to save changes made.
sFlow Poller Settings
The following windows will allow the user to configure the settings for the Switch’s counter poller. This mechanism will take a
poll of the IF counters of the Switch and then package them with the other previously mentioned data into a datagram which will
be sent to the sFlow Analyzer Server for examination. To configure the settings for the sFlow Counter Poller, click the
Administration
link, open the
sFlow
folder and click
sFlow Poller
Settings
, which will produce the following window,
displaying the parameters for the sFlow Counter Poller.
Figure 6- 59. sFlow Counter Poller Settings window
The following fields are displayed:
Parameter Description
Port
Displays the port from which packet counter samples are being taken.
Analyzer Server ID
Displays the ID of the Analyzer Server where datagrams, containing the packet counter polling
information taken using this polling mechanism, will be sent.
Polling Interval
(sec)
The Polling Interval displayed here, is measured in seconds and will take a poll of the IF
counters for the corresponding port, every time the interval reaches 0 seconds.
Modify
Click this button to modify the settings for this entry. The
sFlow Sampler Settings Edit
window will be produced for the user to configure.
Delete
Click the
of the corresponding entry to be deleted.
76