To set the Access Rule for the Packet Content Mask, adjust the following parameters and click Apply.
Parameter
Description
Profile ID
This is the identifier number for this profile set.
Mode
Select Permit to specify that the packets that match the access profile are forwarded
by the Switch, according to any additional rule added (see below).
Select Deny to specify that packets that do not match the access profile are not
forwarded by the Switch and will be filtered.
Access ID
Type in a unique identifier number for this access. This value can be set from 1 - 50.
Type
Selected profile based on Ethernet (MAC Address), IP address or Packet Content
Mask.
Ethernet instructs the Switch to examine the layer 2 part of each packet header.
IP instructs the Switch to examine the IP address in each frame's header.
Packet Content Mask instructs the Switch to examine the packet header.
Priority
Specify a value if you want to change the 802.1p user priority of a packet that meets
the specified criteria (applies in the Switch only) to the specified value. Otherwise, a
packet will have its incoming 802.1p user priority re-written to its original value before
being transmitted.
Replace Priority
Check this option if you want to change the 802.1p user priority of a packet that meets
the specified criteria, will apply in the switch and over-write the value in the 802.1p field
of the packet (if present) with the specifed value. Otherwise, a packet will have its
incoming 802.1p user priority re-written to its original value before being transmitted
from the Switch.
Offset
This field will instruct the Switch to mask the packet header beginning with the offset
value specified:
value (0-15) - Enter a value in hex form to mask the packet from the beginning of the
packet to the 16th byte.
value (16-31) - Enter a value in hex form to mask the packet from byte 16 to byte 31.
value (32-47) - Enter a value in hex form to mask the packet from byte 32 to byte 47.
value (48-63) - Enter a value in hex form to mask the packet from byte 48 to byte 63.
value (64-79) - Enter a value in hex form to mask the packet from byte 64 to byte 79.
Port
The user may set the Access Profile Tableon a per-port basis by entering an entry in
this field. Stackable Switches must specify the Unit number and Port number
separated by a semicolon (for example 1:34 specifies port thirty-four on Switch number
one). Entering all will denote all ports on the Switch.
To view the settings of a previously correctly configured rule, click in the Access Rule Table to view the following
screen: