Troubleshooting
Troubleshooting
237
Vertical blank lines are found
on printed copies.
The Thermal Print Head of the Master
Making Unit or the Scanner Glass of
ADF unit (Option) has been stained
with dirt, white-out, etc.
Gently wipe the Thermal Print Head or
Scanner Glass with a soft cloth.
)
p.215
The unwanted background of
an original is picked up on
copies.
If newspaper or colored (coloured)
paper is used as an original, the
background is picked up on copies.
Lighten the “Contrast” and create a new
master.
)
p.54
Dirt is found on printed copies. The Glass Platen (and/or the ADF
Scanner Glass) is not clean.
Clean the Glass Platen (and/or the ADF
Scanner Glass).
)
p.215
The edges of printed copies
are smudged with ink.
Larger size of paper than the original
was placed on the Paper Feed Tray
at the time of the master-making
process.
Because a master was made according to
a larger size than the original, the edges of
the original were processed as shadows.
Set the same size of paper as the original
and perform the master-making operation
again. Or attach tape as described below
to solve the problem.
Did you use
[Max. Scan]
setting
when making the master?
When printing thick paper such as
cards, corners of the paper contacted
and damaged the master.
Make another master and print with the
new master. Or pull out the Print Drum
(Cylinder) and attach cellophane tape to
the damaged section on the master.
However, if attached with cellophane tape,
a master may not been properly sent to
the Master Disposal Box.
Problem
Possible Cause
Action
CAN_EN.book Page 237 Friday, September 21, 2007 10:42 AM