Objet Objet30 User Manual - page 129
DOC-24000 Rev. C
7–49
Objet30 User Guide
Replacing the
UV Lamp
The UV lamp used for curing models has a long, but limited, working life.
The Objet service engineer tests its effectiveness during regular
maintenance checks, and replaces it, if necessary. If, for any reason, you
need to replace the UV lamp, follow these instructions:
1. Make sure the Objet30 printer is in offline mode.
Figure 7-70: Offline mode indicator (red)
The online/offline button the printer interface should be red. If not, click
it to switch the printer to offline mode.
2. Start the UV Lamp Replacementwizard.
From the Options menu of the printer interface (see figure 7‐33 on
page 26), select
Wizards > UV Lamp Replacement
.
3. Make sure that the build tray is empty, and confirm this in the wizard
screen. Then, close the printer cover and click
Next
.
Figure 7-71: “Empty tray” confirmation screen
The axes move to the “home” position.
WARNING: Before continuing, make sure that the safety interlock in the
printer cover is not defeated, and that the lamp is not hot.