Cabletron Systems FRM User Manual - page 130
9-6
Frame Relay Module 4. 0 User G uide, Rev 01
SNA Port Parameters
1
Although 10 characters can be entered, only the first 8 will be recognized by some
remote manager devices.
2
Can sometimes be changed without disabling the link—see explanation.
3
This parameter is relevant only if
Physical Port Interface
is something other than
RS-
232
and
Generate Clock
is
Y
.
4
This parameter is relevant only if
SNA Type
is
2
(HPAD).
Table 9-1 SNA Port Parameters
Parameter
Valid Values
Default Value
Port Type
SNA
(not valid here)
Name
up to 8 characters
1
none
Physical Port Interface
see explanation
see explanation
Blocked Port Flag
Y/N
N
Line Speed
see explanation
none
No Data Poll Peri od
(ms)
1–500
40
No Resp Poll Per iod
(ms)
40–9999
2000
Maximum Retransmissions
0–99
5
Outstanding Frames
2
1–128
7
Generate Clock
Y/N
Y
Rcv Clock (TT) from DTE
3
Y/N
N
SNA Type
0–3
1
NRZ
Y/N
Y
Packet Si ze
16–4096
(bytes)
1024
Disable Request Di sconnect
4
Y/N
N
LPDA Support
0–2
0
(none)
Idle Fill Character
0xFF, 0x7E
0xFF
Inactivi ty Timer
(sec)
4
15–250
50
L1-Duplex
Ful l/Half
Ful l