Cabletron Systems FRM User Manual - page 339
Syst em Events
21-19
Meaning:
The data packet size (MAXDPS) on the trunk caused a greater traffic
load than the configured Bandwidth Allocation Group would allow,
so the node adjusted the bandwidth allocated to this trunk.
Action:
None.
493.
IPX Route File Upd: IPXRSUB.DAT
Severity:
4
Meaning:
The IPX Route file has been updated.
Action:
None.
494.
Alloc Error on Master SNMP Agent
Severity:
1
Meaning:
A buffer could not be allocated to process an SNMP message.
Action:
None.
500.
BPAD:Invalid Q Pkt “n” - PL
Severity:
3
Meaning:
An invalid Q packet has been received, disabling the port.
Action:
This error creates a file DMP(line #).DAT on the node’s disk. Copy
this file to a diskette and send it to
Cabletron Systems Technical
Support
(see page 21-4) for analysis. Meanwhile, re-enable the port
(
[B], [A], [C]
from the Main Menu), and normal operation should be
established.
501.
BPAD:Invalid Pkt “n” - PL
Severity:
3
Meaning:
An invalid packet has been received, disabling the port.
Action:
Take the same action as for message
500
.
502.
BPAD:Invalid MSG “n” - Link
Severity:
3
Meaning:
An invalid message has been received, disabling the port.
Action:
Take the same action as for message
500
.
503.
BPAD:Invalid MSG “n” - Exchange
Severity:
3
Meaning:
An invalid message has been received, disabling the port.
Action:
Take the same action as for message
500
.
504.
BPAD:Invalid CUA “n” DUA “n”
Severity:
3
Meaning:
An invalid message has been received, disabling the port.
Action:
Take the same action as for message
500
.