Cabletron Systems FRM User Manual - Configuring Subscriber Ids
Configuring BSC Batch
11-7
Subscriber Parameters
Sq
is simply a line number to ease selection of a line on the screen to change. To move to
another line, press
[A]
and enter the sequence number.
Local Sub
is the calling address used by the local device. A
Subscriber ID record
(see
page 11-
7
) must also be configured for this address.
Remote Sub
is the called address used for calls by the local device. A
Subscriber ID record
(see
page 11-7
) must also be configured for this address.
If the BSC port is one end of a connection to a logical X.25 port in the FRM, this
address must match a Subscriber ID configured for the logical port.
Atcl
(Autocall) causes a BSC device to automatically the remote end when it becomes
active.
Rtytm
is the Retry Timer, which determines the time between autocall retries.
Rty#
is the maximum number of times an autocall will be sent. Note that a value of
0
allows
indefinite retries.
Del
lets you delete the remote subscriber that is currently highlighted. You will be
prompted:
Delete "n,"
where
"n"
is the sequence number. Pressing
[Y]
will delete that
line and move all entries below it up one sequence number.
Configuring Subscriber IDs
This operation configures the called and calling addresses that will be used in X.25
call setup if BSCI is being transported over a logical X.25 port. To complete the con-
nection, the software must recognize where the call is coming from (calling address)
and where it is going (called address).
To display a list of current Subscriber IDs (addresses), press
[A]
at the Connections and
Routing Paths Menu
(or
[A], [D], [A]
from the Main Menu).
To add or change a Subscriber ID, press
[B]
at the Connections and Routing Paths
Menu. When prompted, enter a Subscriber ID of up to 15 digits. (ID conventions are
described on
page 8-22
.)