Cabletron Systems FRM User Manual - page 277
St atus Displays
19-5
Figure 19-4 Virtual Connections Display on Non-Frame Relay Port
[C],[C]
from Main Menu
Information in this Display:
●
Seq
– is a sequence number used to identify the connection.
●
I
– is the logical interface:
P
= PVC,
S
= SVC
●
D
– is the direction of the connection:
I
= Incoming,
O
= Outgoing.
●
LCN
– is the logical channel number.
●
State
:
Data_trans
– means that call processing was successful and the con-
nection is in the data transmission state.
Call_setup
– means that the attached device is waiting for Call Accept.
Clearing
– means that the attached device is in Call Clear state, waiting
for Clear Confirmation.
Resetting
– means that a Reset has been sent to the remote device, and the
attached device is waiting for a Reset Confirmation.
Port_down
– is self-explanatory.
Connected
– means that a connection has been established.
Not_conect
– means that a connection has not been established or has
been broken.
Undefined
– means that the port is in some unknown state.
●
Subscriber
– identifies the Calling Address of each end of the connection.
●
RLP
– is the RLP number, with the following exceptions), except for a remote
control, file transfer, or alarm connection, in which case this number is always
253
.
●
P
– is the port number (
0-7
are physical ports,
8–63
are logical ports), unless
RLP
is
253
, in which case:
66
= Remote control,
67
= File transfer,
68
= Alarm con-
nection.
N ode Name= node_xyz
Conn ection S tatus Disp lay Menu (Page 1)
RLP: 0
Port: 0
From:
To:
Seq
I
D
LC N
S tate
S ubs criber R LPP LC N State
Su bscrib er
1
S
O
4095
D ata_tran s 100000100 2
0
4095 Data_trans 120000110
2
S
I
500
D ata_tran s 1100001000 1
5
10
Data_trans 111000120
3
P
I
255
Port_down
0
3
0
Not_conect
4
S
I 10
D ata_tran s 110010000 253 3
6
Data_trans 33333