Cabletron Systems FRM User Manual - Displaying Port Signals
19-6
Frame Relay Module 4. 0 User G uide, Rev 01
Displaying Port Signals
This display lists basic configuration and line status for all serial ports on a specified
RLP, as well as signal states (on/off) at the physical interfaces.
Press
[D]
at the Status Displays Menu and, when prompted, enter an RLP number:
0–2
. The display will show the first four ports, and pressing
[PgDn]
will display the
other four ports.
Figure 19-5 Port Signals Display
[C],[D]
from Main Menu
Information in this Display
●
Port Number
– is self-explanatory.
●
Phy Interface
– is the type of connector on the I/O cable exiting the port's I/O box
connector toward the subscriber device. (This information is taken from the Port
record.)
●
Port Config
– is the port type (
FRL
,
SNA
,
X25
, etc.) as configured in the Port
record. If no record has been created for this port,
No Config
is displayed on this
line and the one below it.
●
Logical Inter
– is the logical interface,
DCE
or
DTE
, as taken from the Port record.
If no record has been created for this port,
No Config
is displayed on this line and
the one above it.
●
Line Speed
– is the speed configured in the Port record.
●
Line Status
:
Failed
(level 2 is down)
Disconnect
(level 2 is up; level 3 is down)
Restart
(level 3 is restarting)
Not_configured
(port is not configured)
Operational
(level 3 is up)
Nod e Name=nod e_xyz
Line Process or Status
RLP: 0
I nterface: RS -422
Port Nu mber:
0
1
2
3
Phy Interface:
X .21
R S-449
X.21
Port Con fig:
FR
No
SN A
FR
Logical Inter:
DTE
Config
D CE
DCE
Line S peed :
1.008M
1.472M
2.048M
Line S tatus:
Oper
Op er
Oper
TD(2)
ON
ON
ON
RD (3)
OFF
ON
ON
RTS (4)
OFF
ON
ON
CTS (5)
OFF
ON
ON
DS R(6)
ON
ON
ON
DC D(8)
ON
ON
ON
TC(15)
ON
ON
ON
RC (17)
ON
ON
ON
DTR (20)
ON
ON
ON \
F2:Next R LP Card
F9:Stop R emote
F10:A bort Remote
PgUp:Firs t 4 Ports
PgDn :Last 4 Ports
Oth ers:Exit08:14:52