6-4
Frame Relay Module 4. 0 User G uide, Rev 01
Figure 6-3 Default Configuration Screen for New Port
[A],[C],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the FRM.
The entry
I/O
identifies the LIC containing the port, and
Link State
will be one of these:
Link_disable
– The link was shut down by an on-line command, is undergoing re-
IPL, or has not yet been established.
Failed
– Some or all modem controls are missing. (This state is passed through
while a port is becoming enabled.)
Link_down
– The link was up, but has gone down.
Disconnect
– Level 2 cannot be established.
Linkup
– The necessary level 1 modem signals are present, and level 2 link is up.
NA
– Some state other than those above has been entered.
To configure the port with the parameter values neccessary for your application, go to
the appropriate chapter:
●
Frame relay
– Chapter 7
●
X.25
– Chapter 8
●
SNA
– Chapter 9
●
BSCI
– Chapter 10
●
BSCB
– Chapter 11
●
Async
– Chapter 12
Configure the protocol that will run over the physical port.
Rmtid= nod exyz
X.25 Port Parameters (screen 1 of 6)
*
R LP: 0
Port: 5
Lin k S tate:
Lin k_disab le
*
I /O: V.35
Databas e
System Memory
A Port Type
X.25
X.25
B Phys ical Port In terface
V.35
V.35
C Blocked Port Flag
N
N
D Line S peed
9600 bp s
9600 bp s
E Modu lo
8
8
F Maximum LA PB Window Size
7
7
G N 2 Retransmit Coun t
5
5
H T1 Retran smit Period (msec)
2000
2000
I
T2 Wait Ack Period (ms ec)
1000
1000
J
T3 Lin k Alive Period (sec)
10
10
K Logical DCE
N
N
L Generate C lock
N
N
M R cv Clock (TT) from DTE
N
N
Option: