Cabletron Systems FRM User Manual - page 368
C-4
Frame Relay Module 4. 0 User G uide, Rev 01
Vary Commands
VARY ACT
Function: Changes the desired status of specified PUs to an active state.
Command:
V NET,ACT, ID={linename[,A|U|C],puname}
Options:
A
= activate all PUs on the line.
U
= activate all PUs on the line whose
ISTATUS = ACTIVE
.
C
= activate all PUs except those that have never been activated
(
NEVAC
). Of those, activate all whose
ISTATUS = ACTIVE
.
VARY INACT
Function: Changes the desired status of specified PUs to an inactive state.
Command:
V NET,INACT, ID={linename[,I|R|F],puname}
Options:
I
= de-activate all PUs on the line immediately.
R
= de-activate, then re-activate, all PUs on the line immediately.
F
= reset all PUs on the line to an inactive state. If appropriate, a
de-activate command will be sent.
Modify Commands
MODIFY CONFIG
Function: Modifies one or more configuration parameters for a specified PU, or
for a specified line if a PU is not specified. There are two
MODIFY
CONFIG
commands:
F NET, CONFIG,ID=“nnnn”
will update the System Memory value(s)
in the FRM record for the SNA Port or LLC2 Host (depending on
the parameter). The changes will be in effect until an on-line
database update or re-IPL of the node is performed, or an
F NET, CONFIG,COMMIT
(see below) is sent.
F NET, CONFIG[,COMMIT]
will update the FRM record’s
Database value(s) with all changes made since the last
COMMIT
,
on-line update of the record, or node IPL.
Command:
F NET, CONFIG,ID={linename[,keyword=value],puname
[,keyword=value]}
Keywords when the line is being modified are listed below. If two
words are shown, either can be used. The parameters are described in
Chapter 9.
Corresponding Parameter
Keyword(s)
in the FRM
Valid Values
NODATA
or
PAUSE
No Data Poll Period
0–125
(ms)
NORESP
or
ACTIVETO
No Resp Poll Period
40–9999
(ms)
GENCLCK
or
CLOCKING
Generate Clock
Y/N
RCVCLOCK
Rcv Clock (TT) from DTE
Y/N
ISTATUS
Blocked Port Flag
Y/N
NRZI
NRZ
Y/N
SPEED
Line Speed
(see
page 9-8
)