Cabletron Systems FRM User Manual - page 86
7-20
Frame Relay Module 4. 0 User G uide, Rev 01
Figure 7-8 Frame Relay PVC Configuration
[A],[D],[E],[B]
from Main Menu
It does not matter which end of the PVC is configured first.
Frame Relay PVC Parameters
1 The DLCI must match the DLCI configured at the remote end of the physical link.
Connection Priority
prioritizes this connection for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
Priorities are configured on all logical interfaces that use a physical frame relay port.
The device processor in the node uses these priorities to help determine the order in
which it will process protocols.
When configuring priorities, be careful to consider the types of
traffic being routed on other connections in the node.
Table 7-5 Frame Relay PVC Parameters
Parameter
Valid Values
Default Value
Connection Priority
0–9
0
Pr imary/Secondar y Nam e
0–31 characters
none
Pr imary/Secondar y DLCI
16–991
1
16
Pr imary/Secondar y RLP
0–3
0
Pr imary/Secondar y Por t
0–7
0
Nod e Name=n ode_xyz
PV C Maintenan ce C onnection I D1
A
PVC Typ e
FRL to FRL
B
C onnection Priority
0
C onnection Between Frame Relay Port...
C
Primary Name
fsu b1
D
Primary DLCI
16
E
Primary RLP
0
F
Primary Port
0
an d Frame Relay Port...
G
S econd ary Name
fsu b5
H
S econd ary DLC I
21
I
S econd ary RLP
1
J
S econd ary Port
2
Option: