Cabletron Systems FRM User Manual - page 51
Configuring Node-Wide Default Parameters
4-3
Database and System Memory Values
Two sets of values exist for Node Defaults parameters: Database values exist in the
software, and are recorded as System Memory values when the node is booted. If the
port type is the same in both sets of values, both sets will be displayed.
Any change you make will be recorded as a Database value, and will be copied to the
System Memory side only if you press
[F7]
. Note that changes will not be actually be
saved to the database until you press
[F3]
to exit the record.
Node Defaults Parameters
All possible parameters on the first two Node Defaults screens are listed in Table 4-1,
and the NetView parameters on the third screen are listed in
Table 4-2
(on page 4-7).
Depending on the values configured for some parameters, other parameters might not
be displayed.
Descriptions of most parameters follow each table.
1
Remember that the software sees uppercase as different from lowercase.
Table 4-1 Node Defaults Parameters
Parameter
Valid Values
Default Value
Node Name
up to 8 characters
none
Remote Control ID
0–15 digits
none
Remote Control Pwd
0–15 characters
1
remote
Fi le Tr ansfer ID
0–15 digits
none
Fi le Tr ansfer Pwd
0–15 characters
1
ftran
Coll ecting Node ID
0–15 digits
none
Coll ecting Node Pwd
0–15 characters
1
al arms
Primary Al arm O utput ID
see footnote
2
none
Primary Al arm O utput Pwd
0–15 characters
1
al arms
Secondary Al arm O utput ID
see footnote
2
none
Secondary Al arm O utput Pwd
0–15 characters
1
al arms
Com. Port Thruput
A–H
H
(9600 bps)
Com. Port Parity
0, 1, 3
0
(none)
Com. Port Stopbit
1, 2
1
Bi ts per Character
7, 8
8
Coll ecting Node
Y/ N
N
Max Congestion
1–50
(%)
50
Min Congesti on
1–50
(%)
25
Peri odi c Status Timer
0–30
(min)
3
1
Li ne Idl e Timer
0–65535
(sec)
0
4
Al arm Autocal l Timer
5–3600
(sec)
60
Al arm Max Retries
0–99
0
(no max)
5