Figure 12-4 Async-to-X.25 PVC Record
[A],[D],[E],[B]
from Main Menu
The same parameters are displayed for an async-to-async PVC.
Async PVC Parameters
1
16, 32, 64 ,128, 256, 512, 1024, 2048, or 4096
. Cannot be greater than the smaller
Maximum Packet Size specified in the port records for both ends of the connection.
2
Cannot be greater than the smaller
Maximum Window Size
specified in the Port records
for both ends of the connection.
Connection Priority
prioritizes this connection for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
Priorities are configured on all logical interfaces that use a physical frame relay port.
The device processor in the node uses these priorities to help determine the order in
which it will process protocols.
Table 12-5 Async PVC Parameters
Parameter
Valid Values
Default Value
Connection Priority
0–9
0
Subscriber Name
0–31 characters
none
Logical Channel
1
1
RLP
0–2
0
Por t
0–63
0
Packet Si ze
128–4096
1
128
Window Si ze
1–7
2
2
N ode Name=n odexyz
PVC Maintenance Con nection ID1
A
PV C Type
A sync PAD to X.25
B
Conn ection Priority
0
C onnection Between A sync Port...
C
Sub scriber N ame
as ub1
D
Logical C hann el
10
E
RLP
0
F
Port
0
G
Packet Size
128
H
Win dow Size
2
an d X.25 Port...
I
Sub scriber N ame
xs ub5
J
Logical C hann el
11
K
RLP
0
L
Port
2
M
Packet Size
128
N
Win dow Size
2
Option: