Cabletron Systems FRM User Manual - page 75
Configuring Frame Relay
7-9
Configuring Frame Relay Ports
Once the necessary Node and RLP parameters have been configured, press
[A]
at the
Port Configuration Menu (or
[A], [C], [A]
from the Main Menu. When prompted, enter:
●
RLP
containing the port:
0–2
. (The default is
0
.) (RLP locations are shown in
Figure 6-1
.)
●
Port
:
0–7
. (The default is
0
.) (Port locations are shown in
Figure 6-2
.)
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See
Table 7-3
on page 7-14
and
Table 7-4
on page 7-15.) The following figure is an example of an existing port.
Figure 7-3 Frame Relay Port Screen 1
[A],[C],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the FRM.
Pressing
[O]
will display a screen similar to the following.
N ode Name=n ode_xyz
Frame Relay Port Parameters (screen 1 of 2)
*
RLP: 0
Port: 0
Link State:
Linku p
*
I/O: V .35
D atabase
Sys tem Memory
A Port Type
Frame Relay
Frame Relay
B Ph ysical Port I nterface
V .35
V.35
C Blocked Port Flag
N
N
D Lin e Sp eed
64K b ps
64K b ps
E Maximum Bytes p er Frame
1600
1600
F Logical D CE
N
N
G Generate Clock
N
N
H Rcv C lock (TT) from D TE
N
N
I
Lin k Man agement
2 Ann ex D
2 Ann ex D
J
N1 Pollin g Cou nt
6
6
K N2 Error Threshold
3
3
L N3 Mon itored Events C ount
4
4
M T1 Link In tegrity Timer
10
10
N T2 Polling Verification Timer
15
15
O Add itional Parameters
Option: