Cabletron Systems FRM User Manual - page 170
11-2
Frame Relay Module 4. 0 User G uide, Rev 01
Configuring BSC Batch Port Records
Once the necessary Node, Line Processor, and protocol parameters have been con-
figured, press
[A]
at the Port Configuration Menu (or
[A], [C], [A]
from the Main Menu.
When prompted, enter:
●
RLP
containing the port:
0–2
. (The default is
0
.) (RLP locations are shown in
Figure 6-1
.)
●
Port
:
0–7
. (The default is
0
.) (Port locations are shown in
Figure 6-2
.)
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See
Table 11-1
on page 11-
3.) The following figure is an example of an existing port.
Figure 11-1 BSC Batch Port Record
[A],[C],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the FRM.
Pressing
[J]
lists more parameters, and pressing
[K]
displays a screen similar to the fol-
lowing. (All BSC Batch parameters are listed in
Table 11-1
.)
Nod e Name=nod exyz
BSC Batch Port Parameters (screen 1 of 2)
*
RLP: 0 Port: 5
Lin k State: Lin kup
*
I/O: V .35
Datab ase
System Memory
A
Port Typ e
BSC Batch
BSC Batch
B
Ph ysical Port In terface
V.35
V.35
C
Blocked Port Flag
N
N
D
Lin e Speed
9600 b ps
9600 b ps
E
Retrans mis sion Period (ms)
2000
2000
F
Maximum Retran smissions
5
5
G Maximum Bytes per Frame
4105
4105
H Generate Clock
Y
Y
I
Rcv Clock (TT) from DTE
N
N
J
Batch Parameters - Screen 2
K Sub scriber In formation - S creen 3
Option: