Intergraph TD-300 Maintenance Manual - page 66
52 Chapter 4 - Maintaining the System
➤
To install the new system hard disk drive:
1.
Disable SCSI termination and set the SCSI ID to the same SCSI ID as
the previous hard disk drive. Refer to the documentation delivered
with the hard disk drive for details.
2.
Secure the new disk drive to the bracket. Slide the disk drive
assembly into the base unit. Ensure the bracket tabs fit into the slots.
3.
Secure the drive to the chassis by installing the screw.
4.
Attach the power cable and SCSI cable to the hard disk drive. The
SCSI cable is keyed to ensure proper insertion. The red stripe (pin 1)
must be adjacent to the power connector.
5.
Close the base unit.
6.
Restart the workstation.
7.
Partition and format the hard disk drive as described in the operating
system documentation.
8.
Install the operating system onto the new hard disk drive as described
in Appendix A, “Installing System Software.”
Note:
For instructions on installing the Solaris 2.5 for x86 operating
system, refer to Intergraph’s Workstation Software Configuration for
Solaris 2.5 for x86.
Replacing the Auxiliary Hard Disk Drive
Auxiliary hard disk drives are located in the drive bays above the CD-ROM
drive.
➤
To remove the auxiliary hard disk drive:
1.
Disconnect the SCSI cable and power cable from the hard disk drive
as shown in the following figure.
2.
Using a quarter-inch nutdriver, remove the two screws from the side
of the hard disk drive.