Server Technology switched pro2 User Manual - page 158
Switched PRO2 – User Guide
Using the Command Line Interface (CLI)
•
158
userfromaddr
Sets to log into the relay SMTP server using the from address.
username
Sets the username for logging into the relay SMTP server.
0-32 characters, spaces are not allowed.
test
Tests the email setting for logging into the relay SMTP.
usesubjloc
Uses the location string as the subject of the relayed emails.
usesubjdef
Uses the default subject as the subject of the relayed emails.
(sentry@macoui).
useusername
Set to log into the relay SMTP server using the SMTP username.
Sub-Parameters
The set email command uses the following sub-parameters:
any
Uses any of the authentication methods described in this table.
crammd5
Uses only CRAM-MD5 for authentication.
digestmd5
Uses only Digest MD5 for authentication
login
Uses only login authentication.
plain
Uses only plain authentication.
none
Uses only no authentication.
Command Access
Admin level only; no access in Demo mode
set energywise
Sets Cisco EnergyWise configuration values.
Command Syntax
set energywise [disabled | enabled]
set energywise port
set energywise domain
set energywise refresh
set energywise secret
Parameters
The set energywise command uses the following parameters:
port
Sets the port number of the EnergyWise host. 1-65535 (default 43440).
domain
Sets the domain of the EnergyWise host. 0-63 characters.
refresh
Sets the refresh rate that sends new EnergyWise discovery packets.
30-600 seconds.
secret
Sets the secret key for the EnergyWise server. 0-80 characters.
Command Access
Admin level only; no access in Demo mode