Garmin G900X Pilot's Manual - page 82
Garmin G900X Pilot’s Guide
190-00726-00 Rev. A
2-22
FLIGHT INSTRUMENTS
2.2 SUPPLEMENTAL FLIGHT DATA
NOTE:
Selecting the
DFLTS
Softkey (a second-level PFD softkey) turns off metric Altimeter display, the Inset
Map, and wind data display.
In addition to the flight insturments, the PFD also displays various supplemental information, including a
generic timer, the Outside Air Temperature (OAT), wind data, the system time, and Vertical Navigation (VNV)
indications.
GENERIC TIMER
The Timer/References Window contains a generic timer, which can be set to count up or down from a
specified time (HH:MM:SS). When the countdown on the timer reaches zero, the digits begin to count up from
zero. If the timer is reset before reaching zero on a countdown, the digits are reset to the initial value. If the
timer is counting up when reset, the digits are zeroed.
Figure 2-30 Timer/References Window
Setting the generic timer:
1)
Select the
TMR/REF
Softkey.
2)
Turn the large
FMS
Knob to select the timer field (hh/mm/ss).
3)
Use the
FMS
Knob to enter the desired time and press the
ENT
Key.
4)
With the UP/DN field highlighted, turn the small
FMS
Knob to select the timer counting direction.
5)
Press the
ENT
Key.
6)
With ‘START?’ highlighted, press the
ENT
Key to start the timer. The field changes to ‘STOP?’.
7)
To stop the timer, press the
ENT
Key with ‘STOP?’ highlighted. The field changes to ‘RESET?’.
8)
To reset the timer, press the
ENT
Key with ‘RESET?’ highlighted. The field changes back to ‘START?’ and the
digits are reset.
9)
To remove the window, press the
CLR
Key or the
TMR/REF
Softkey.